Special Cables

Flat Twin Flexible Cables

Conductor:Soft annealed circular copper finely stranded

Insulation: P.V.C. rated 70 ° C  for continuous voltage Rated 250 V according to Egyptian Standard No. 182

Assembly:Two insulated conductors are laid parallel

Sheath: Grey / Black / White

Colour of Core: Red - Blue

a) With Sheath Thickness

Nominal Cross- Sectional Area
Conductor No. of Wires x Diameter of Wire
Nominal Insulation Thickness
Nominal Sheath Thickness
Dimensions
Total Weight (approx.)
mm2
No. x mm
mm
mm
mm
kg/km
0.25
4 x 0.3
0.5
0.6
4.2 x 3.1
25
0.5
7 x 0.3
0.5
0.7
5.5 x 3.5
30
0.75
11 x 0.3
0.6
0.7
6.1 x 4.2
43.5
1
14 x 0.3
0.7
0.8
7.1 x 4.35
60
1.5
21 x 0.3
0.7
0.8
7.6 x 4.06
73
2
28 x 0.3
0.7
0.8
8.1 x 4.85
86

b) Without Sheath Thickness

0.25
4 x 0.3
0.5
____
____
13.1
0.5
7 x 0.3
0.5
____
____
19.1
0.75
11 x 0.3
0.6
____
____
26.5

2- Twin Twisted P.V.C. Insulated Conductor

Description: Two flexible single core copper wires P.V.C. insulated are twisted without outer sheath.

Specification: According to the specification of flexible single core copper wire insulated P.V.C.

Thickness of P.V.C.: For single wire not less than 0.8 mm

 

3-  Welding Cables

Conductor: Circular single cable with flexible copper conductor

Insulation: P.V.C. according to VDE 0250 rated  70 ° C  for continuous operation

Nominal Cross- Sectional Area
Conductor (No. of Wires x Diameter of Wire)
 
Insulation Thickness (min.)
Overall Diameter
Total Weight (approx.)
mm2
No. x mm
mm
mm
kg/km
25
133 x 0.5
1.3
10.1
304
35
182 x 0.5
1.3
12.6
424
50
259 x 0.5
1.4
13.3
567
70
361 x 0.5
1.4
15.3
761

 

4- Vehicle Cables

Conductor: - Circular single core flexible
- Soft annealed circular copper

Insulation: P.V.C. insulated 250 V according to BSS 1862  rated  70 ° C  for continuous operation

Nominal Cross- Sectional Area
 No. of Wires x Diameter of Wire
 Nominal Insulation Thickness 
Overall Diameter (approx.)
Total Weight (approx.)
mm2
No. x mm
mm
mm
kg/km
0.75
24 x 0.2
0.6
2.45
12.2
1
32 x 0.2
0.7
2.75
16.1
1.5
21 x 0.3
0.7
3.00
21.2
2
28 x 0.3
0.7
3.25
25.9
2.5
35 x 0.3
0.8
3.7
33.7
3
42 x 0.3
0.8
4.05
41.5
4
56 x 0.3
0.8
4.25
49.5
6
84 x 0.3
0.9
5.1
72.6
1.4 for spark plug
20 x 0.3
2.75
7.00
68.1

Cables for Vehicle Battery

25 133 x 0.5 1.3 10.10 304.3
35 190 x 0.5 1.3 12.10 424
50 259 x 0.5 1.4 13.30 567
70 361 x 0.5 1.4 15.30 761

 

5- Symmetrical T. V. Cable

Description:A flat seven copper wires for two connection with solid insulation of stablized P.V.C. according to IEC 96-2

Conductor: Soft annealed copper conductor of seven stranded wires.

Insulation: Two conductors are insulated together in flat formation with solid stabilized P. V.C.
Two conductors are insulated together in flat formation with solid stabilized P. V.C.

Characteristic Impedence: 300

Conductor:No. of wires x diameter of wire = 7 x 0.3 mm

Diameter of conductor 0.9 mm
Dimensions:t - min.   =   0.3 mm
w - max.=10.5 mm
b - min.  =0.5 mm

Attenuation: At 200 MHZ       7 db/100 m
At 400 MHZ         10.5 db/100 m

 

Developed by NetEgypt.com © 2004-2005 Ghazala Cables ® All Rights Reserved.